Single Gas Clip
- H2S Measuring range: 0-100 ppm
- Low alarm limit: 10 ppm – High alarm limit: 15 ppm
- CO Measuring range: 0-300 ppm
- Low alarm limit: 35 ppm – High alarm limit: 200 ppm
- O2 Measuring range: 0-30% by vol.
- Low alarm limit: 19.5% – High alarm limit: 23.5%*
Note: Alarm set points listed above are factory default. These set points can be changed using the GCT IR Link (sold separately).
Finally a reliable portable single gas detector that ensures constant protection against toxic gas in the harshest of working conditions.
- Unmatched sensor reliability for H2S, CO or O2
- Adjustable alarm set points & real-time gas reading capability
- 0.1 ppm resolution for H2S sensor and display
- Two-way IR comms for event downloads, bump tests & updates
- Programmable individual detector identification
- Simple to use one button operation
- “Bump Check” confirmation/identification
- No hidden service charges or maintenance fees
- Lightweight & durable – clamps on tight with alligator clip


- TEMPERATURE:
H2S: -40°C to +50°C/-40°F to +122°F
CO: -40°C to +50°C/-40°F to +122°F
O2: -35°C to +50°C/-31°F to +122°F
- HUMIDITY
5% to 95% RH (non-condensing)
- GASES
H2S Measuring range: 0-100 ppmLow alarm limit: 10 ppm – High alarm limit: 15 ppm
CO Measuring range: 0-300 ppmLow alarm limit: 35 ppm – High alarm limit: 200 ppm
O2 Measuring range: 0-30% by vol.Low alarm limit: 19.5% – High alarm limit: 23.5%*
Note: Alarm set points listed above are factory default. These set points can be changed using the GCT IR Link (sold separately).
- USER OPTIONS
Custom user message, Bump due LED, Bump test interval, Calibration gas percentage, Calibration interval, Display real-time gas, readings or time remaining, Self-test interval, Low alarm set point, High alarm set point
- CERTIFICATIONS & APPROVALS
UL-913 & CAN/CSA-C22.2 No. 157
Class I Divisions 1 & 2, Groups A, B, C and D
Class I, Zone 0, AEx ia IIC T4 Ga
UL 60079-0, UL 60079-11
ATEX: II 1 G T4 Ex ia IIC T4
IECEx: EX ia IIC T4
InMetro: IEx 15.0058 Ex ia IIC T4 Ga(-40 ̊C (H2S,CO) / -35 ̊C (O2) ≤ Ta ≤ +50 ̊C


- DISPLAY
High viewing angle Alphanumeric Liquid Crystal Display
- LOGS
25 Events – newer events replace older events
- TESTS
Full function self-test upon activation and every 20 hours. Continuous automatic battery tests


- SIZE & WEIGHT
85.5 x 48 x 29 mm (3.4” H x 1.9” W x 1.1” D)76g (2.7 oz.)
- BATTERY LIFE
Two Years
- ALARMS
Visual, vibrating & audible (minimum 95 dB)
Detector life countdown (EOL), Low, High & Over limit (OL)
Request More Information
By submitting your information into this form, you are confirming you have read and accepted the terms presented within the Martek Marine Privacy Policy. We will never pass your details to anyone else. We will use your information to provide a personalised and tailored service when we communicate with you. We will also ensure your data is securely transmitted to our secure data environment where it will be protected within the Microsoft Dynamics 365 infrastructure.